Creatinine clearance after cimetidine administration in a new short procedure: comparison with plasma and renal clearances of iohexol - Université Paris-Est-Créteil-Val-de-Marne
Journal Articles Clinical Kidney Journal Year : 2020

Creatinine clearance after cimetidine administration in a new short procedure: comparison with plasma and renal clearances of iohexol

Abstract

Abstract Background Creatinine clearance after cimetidine administration (Cim-CreatClr) was once proposed as a method of glomerular filtration rate (GFR) measurement, but has been largely abandoned. We investigated whether a new short procedure for Cim-CreatClr determination could be considered an appropriate method for GFR measurement. Methods A 150-min protocol involving oral cimetidine administration was developed to determine Cim-CreatClr. In total, 168 patients underwent simultaneous assessments of creatinine clearance before and after cimetidine administration [basal creatinine clearance (Basal-CreatClr) and Cim-CreatClr, respectively], renal iohexol clearance and plasma iohexol clearance (R-iohexClr and P-iohexClr, respectively). We compared the agreement between the various methods of GFR measurement, using Bland–Altman plots to determine biases, precisions (standard deviation of the biases) and accuracy (proportions of GFR values falling within 10, 15 and 30% of the mean: P10, P15 and P30, respectively). Results After cimetidine administration, Basal-CreatClr decreased by 19.8% [95% reference limits of agreement (95% LoA): −2.2 to 41.7%]. The bias between Cim-CreatClr and P-iohexClr was −0.6% (95% LoA −26.8 to 28%); the precision was 14.0%; P10, P15 and P30 were 57.1% [95% confidence interval (95% CI) 49.3 to 64.7%], 73.2% (95% CI 65.8 to 79.7%) and 97.0% (95% CI 93.2 to 99.0%), respectively. Due to the positive bias (16.7%; 95% LoA −3.6 to 36.9%) of Cim-CreatClr relative to R-iohexClr, accuracy of Cim-CreatClr relative to R-iohexClr was poor despite a good precision (10.3%). Conclusions Our study shows a high level of agreement between Cim-CreatClr and P-iohexClr. These results suggest that this short Cim-CreatClr procedure is a valid method for GFR measurement, which might be useful, in particular, in situations in which P-iohexClr is not suitable or not available.
Fichier principal
Vignette du fichier
sfz087.pdf (1.3 Mo) Télécharger le fichier
Origin Publisher files allowed on an open archive

Dates and versions

hal-04155489 , version 1 (07-07-2023)

Identifiers

Cite

Thomas Stehlé, Khalil El Karoui, Mehdi Sakka, Ahmad Ismail, Marie Matignon, et al.. Creatinine clearance after cimetidine administration in a new short procedure: comparison with plasma and renal clearances of iohexol. Clinical Kidney Journal, 2020, 13 (4), pp.587-596. ⟨10.1093/ckj/sfz087⟩. ⟨hal-04155489⟩
12 View
14 Download

Altmetric

Share

More