Potential of Multiplex Polymerase Chain Reaction Performed on Protected Telescope Catheter Samples for Early Adaptation of Antimicrobial Therapy in ARDS Patients - Université Paris-Est-Créteil-Val-de-Marne
Article Dans Une Revue Journal of Clinical Medicine Année : 2022

Potential of Multiplex Polymerase Chain Reaction Performed on Protected Telescope Catheter Samples for Early Adaptation of Antimicrobial Therapy in ARDS Patients

Keyvan Razazi
Flora Delamaire
Vincent Fihman
Mohamed Ahmed Boujelben
  • Fonction : Auteur
Nicolas Mongardon
Ségolène Gendreau
Quentin de Roux
  • Fonction : Auteur
Nicolas de Prost
Guillaume Carteaux
  • Fonction : Auteur
Paul-Louis Woerther
Armand Mekontso Dessap

Résumé

Background: Diagnosis of co/superinfection in patients with Acute Respiratory Distress Syndrome (ARDS) is challenging. The FilmArray Pneumonia plus Panel (bioMérieux, France), a new rapid multiplex Polymerase Chain Reaction (mPCR), has never been assessed on a blinded protected telescope catheter (PTC) samples, a very common diagnostic tool in patients under mechanical ventilation. We evaluated the performance of mPCR on PTC samples compared with conventional culture and its impact on antibiotic stewardship. Methods: Observational study in two intensive care units, conducted between March and July 2020, during the first wave of the COVID-19 pandemic in France. Results: We performed 125 mPCR on blinded PTC samples of 95 ARDS patients, including 73 (77%) SARS-CoV-2 cases and 28 (29%) requiring extracorporeal membrane oxygenation. Respiratory samples were drawn from mechanically ventilated patients either just after intubation (n = 48; 38%) or later for suspected ventilator-associated pneumonia (VAP) (n = 77; 62%). The sensitivity, specificity, positive, and negative predictive values of mPCR were 93% (95% CI 84–100), 99% (95% CI 99–100), 68% (95% CI 54–83), and 100% (95% CI 100–100), respectively. The overall coefficient of agreement between mPCR and standard culture was 0.80 (95% CI 0.68–0.89). Intensivists changed empirical antimicrobial therapy in only 14% (18/125) of cases. No new antibiotic was initiated in more than half of the CAP/HAP pneumonia-suspected cases (n = 29; 60%) and in more than one-third of those suspected to have VAP without affecting or delaying their antimicrobial therapy. Conclusions: Rapid mPCR was feasible on blinded PTC with good sensitivity and specificity. New antibiotics were not initiated in more than half of patients and more than one-third of VAP-suspected cases. Further studies are needed to assess mPCR potential in improving antibiotic stewardship.

Dates et versions

hal-04298094 , version 1 (21-11-2023)

Identifiants

Citer

Keyvan Razazi, Flora Delamaire, Vincent Fihman, Mohamed Ahmed Boujelben, Nicolas Mongardon, et al.. Potential of Multiplex Polymerase Chain Reaction Performed on Protected Telescope Catheter Samples for Early Adaptation of Antimicrobial Therapy in ARDS Patients. Journal of Clinical Medicine, 2022, 11 (15), pp.4366. ⟨10.3390/jcm11154366⟩. ⟨hal-04298094⟩
4 Consultations
0 Téléchargements

Altmetric

Partager

More