Wearable cardioverter-defibrillator in patients with a transient risk of sudden cardiac death: the WEARIT-France cohort study

Rodrigue Garcia
Nicolas Combes
  • Fonction : Auteur
Pascal Defaye
  • Fonction : Auteur
Kumar Narayanan
  • Fonction : Auteur
Laurence Guedon-Moreau
  • Fonction : Auteur
Serge Boveda
  • Fonction : Auteur
Hugues Blangy
  • Fonction : Auteur
Jérôme Bouet
  • Fonction : Auteur
Florent Briand
  • Fonction : Auteur
Philippe Chevalier
  • Fonction : Auteur
Yves Cottin
  • Fonction : Auteur
Antoine da Costa
  • Fonction : Auteur
Bruno Degand
  • Fonction : Auteur
Jean-Claude Deharo
  • Fonction : Auteur
Romain Eschalier
  • Fonction : Auteur
Fabrice Extramiana
  • Fonction : Auteur
Marc Goralski
  • Fonction : Auteur
Benoit Guy-Moyat
  • Fonction : Auteur
Yves Guyomar
  • Fonction : Auteur
Jean-Sylvain Hermida
  • Fonction : Auteur
François Jourda
  • Fonction : Auteur
Mohanad Mahfoud
  • Fonction : Auteur
Vladimir Manenti
  • Fonction : Auteur
Jacques Mansourati
Angéline Martin
  • Fonction : Auteur
Jean-Luc Pasquié
  • Fonction : Auteur
Philippe Ritter
  • Fonction : Auteur
Anne Rollin
  • Fonction : Auteur
Thierry Tibi
  • Fonction : Auteur
Arab Yalioua
  • Fonction : Auteur
Daniel Gras
  • Fonction : Auteur
Nicolas Sadoul
  • Fonction : Auteur
Olivier Piot
  • Fonction : Auteur
Christophe Leclercq
  • Fonction : Auteur
Eloi Marijon

Résumé

Abstract Aims We aimed to provide contemporary real-world data on wearable cardioverter-defibrillator (WCD) use, not only in terms of effectiveness and safety but also compliance and acceptability. Methods and results Across 88 French centres, the WEARIT-France study enrolled retrospectively patients who used the WCD between May 2014 and December 2016, and prospectively all patients equipped for WCD therapy between January 2017 and March 2018. All patients received systematic education session through a standardized programme across France at the time of initiation of WCD therapy and were systematically enrolled in the LifeVest Network remote services. Overall, 1157 patients were included (mean age 60 ± 12 years, 16% women; 46% prospectively): 82.1% with ischaemic cardiomyopathy, 10.3% after implantable cardioverter-defibrillator explant, and 7.6% before heart transplantation. Median WCD usage period was 62 (37–97) days. Median daily wear time of WCD was 23.4 (22.2–23.8) h. In multivariate analysis, younger age was associated with lower compliance [adjusted odds ratio (OR) 0.97, 95% confidence interval (CI) 0.95–0.99, P < 0.01]. A total of 18 participants (1.6%) received at least one appropriate shock, giving an incidence of appropriate therapy of 7.2 per 100 patient-years. Patient-response button allowed the shock to be aborted in 35.7% of well-tolerated sustained ventricular arrhythmias and in 95.4% of inappropriate ventricular arrhythmia detection, finally resulting in an inappropriate therapy in eight patients (0.7%). Conclusion Our real-life findings reinforce previous studies on the efficacy and safety of the WCD in the setting of transient high-risk group in selected patients. Moreover, they emphasize the fact that when prescribed appropriately, in concert with adequate patient education and dedicated follow-up using specific remote monitoring system, compliance with WCD is high and the device well-tolerated by the patient.

Dates et versions

hal-04395390 , version 1 (15-01-2024)

Identifiants

Citer

Rodrigue Garcia, Nicolas Combes, Pascal Defaye, Kumar Narayanan, Laurence Guedon-Moreau, et al.. Wearable cardioverter-defibrillator in patients with a transient risk of sudden cardiac death: the WEARIT-France cohort study. EP-Europace, 2021, 23 (1), pp.73-81. ⟨10.1093/europace/euaa268⟩. ⟨hal-04395390⟩

Collections

IMRB UPEC
11 Consultations
0 Téléchargements

Altmetric

Partager

More